KCM161FQx Insulation Monitor, System Voltage up to 1.4kV with Non-Latching Output, Analog Output, Special for Frequency Converter Systems

$ 1,031.00$ 1,130.00

INSULATION MONITOR FOR NON-GROUNDED AC NETWORKS
Download:
KCM161FQx Brochure

Description

KCM161FQx

Insulation Monitor, System Voltage up to 1.4kV, with Non-Latching Output and Analog Output, Special for Frequency Converter Systems

  • Designed for non-grounded networks with Frequency Converters
  • Direct connection up to 690V system voltage, up to 1,4kV with HV Adapter
  • Monitoring during both live and standby conditions
  • For use in land, marine and offshore installations
  • Parallelling Disable Function
  • Immune to earth capacitance and voltage surges
  • Analogue output proportional to meter reading
  • Optional slave indicator
  • Scale range: 0-1000kΩ – ∞ (>6MΩ)
Application
Our the digitally controlled KCM161FQx monitors insulation level between a non-grounded (IT) AC mains and its protective earth, regardless of whether the mains is live or non-live (standby). The unit is for land, marine, offshore, sub-sea and ocean floor use.
An AC or DC auxiliary voltage is required for the unit, if powered from a separate source the network can also be monitored during inactive (standby) conditions. Only ONE KCM161FQx can be connected to each IT-system. The  ohmmeter and the triple-zone status LEDs give at a glance the clear safety message:
  • ALARM
  • WARNING
  • HEALTHY
General
IDV MEASURING PRINCIPLE
Insulation is measured between the complete galvanically interconnected AC network and its protective earth. The unit injects a sequentially coded measuring signal into the monitored system. The signal flows to ground via the path of the insulation fault, the level of flow indicates the insulation resistance. The measuring accuracy is not influenced by any normal kind of load attached to the AC network. Trip levels and delays are settable on unit rear. A trip LED flashes when the trip level is passed, the relay trips when the delay has elapsed. The timer resets if the fault is removed during countdown.
MEGGER SAFE
When auxiliary power is OFF the unit input is automatically protected against “megger” test voltages up to 1.4kVDC, and incorrect measurements caused by the unit’s input impedance are avoided.
OUTPUTS
All F versions have an isolated analogue output proportional to meter reading. If output is used for remote meter reading, we recommend 0-1mA for the slave indicator.
SAFETY
The KCM161x range is designed to comply with specification AODC035 “Code of Practice for the Safe Use of Electricity Under Water” issued by IMCA.
INTELLIGENT SETTING ASSISTANCE
KCM161x has a built-in Assistance tool for setting/verification of the trip levels and the analogue output.
When either the Warning or Alarm potentiometer on the rear is operated by user, the meter goes into Assistance Mode and meter reading and analogue output will reflect the potentiometer setting.

Additional information

Weight 2 lbs
Dimensions 9 × 9 × 9 in
Aux Supply

100-120VAC Aux Supply, 200-240VAC Aux Supply, 380-415VAC Aux Supply, 440-480VAC Aux Supply, 12-24VDC Aux Supply

Analog Output

0-10mA, 0-20mA, 4-20mA, 0-10VDC