KEC115, KEC116 and KEC117 AC Generator Short Circuit & Over Current Protection, Output Relays, Optional Analog Output

Call for price

Generator Short Circuit & Over Current Protection, Output Relays and Optional Analog Output
Download:
KEC115, KEC116x & KEC117x Brochure

Description

KEC115, KEC116 & KEC117

Generator Short Circuit & Over Current Protection, Output Relays and Optional Analog Output

  • Three phase Current Protection with VATOR, Definite time or Two level O/C trip function
  • “PREDICTOR” function, The Blackout Preventer
  • “Pathfinder” function eases fault finding
  • Independent ammeter with Full Load Current (FLC) mark on scale
  • Triple relay operation gives more flexibility
  • Built-in fast analogue Amp or Hz transducer (Optional)
  • Application
    The digitally controlled true RMS measurement on the KEC115x provides precision (1,0%) three phase current protection for AC generators, motors, transformers etc. for alarms or tripping of a non-essential load or breaker. It can also be supplied with a built-in current (KEC116x) or frequency transducer (KEC117x).
    The independent class 1,5 moving iron ammeter input (term. 26 & 27) MUST be externally connected or switched to read individual phase currents.
    User settable trip levels and delays. LEDs flash during countdown and indicate the alarm status. The “Pathfinder” function identifies the phase causing the trip by the flashing pattern of the LED.
    KEC115x is the standard range with relay outputs for over current and short circuit current trip. The highest phase current will activate the OC/SC levels.
    KEC116x range also include a fast response (<50mS) built-in Current transducer proportional to the HIGHEST phase current signal. This may be used as an input to a control system, to detect abnormal current conditions (loss of excitation etc).
    KEC117x range also include a fast response (<50mS) built-in frequency transducer. This may be used as an input to a control system.
    VATOR (VAriable Time Overcurrent Release function)
    Versions with VATOR function have definite trip time up to 150% generator over current load. Between 150-200% the trip time will be reduced dynamically based on a calculated curve to maintain thermal capability protection and selective protection between parallelled generators.
    Refer to the VATOR calculation excel sheet for further details of the time release curve.
    PREDICTOR
    The main feature of the Predictor function is to open bus-tie breakers or trip heavy loads to prevent a total blackout situation. The predictor relay(s) trips at set over current (O/C) or short circuit current (S/C) level, prior to the generator breaker trip. If the overload condition is still present after this load reduction the generator breaker will trip 1sec or 200mS later relative to set O/C or S/C time delays.
    The combination of VATOR and Predictor is the ultimate solution for electrical selectivity and thermal protection of parallelled generators.
    PATHFINDER
    The Pathfinder indicates the phase causing an over current or short circuit trip by the flashing pattern of the relevant LED. When either short circuit or over current trips have operated the relevant LED will flash in the following pattern to indicate the phase producing the trip.
    Unit meets IEC60092-504 and relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively, to comply with Classification Societies requirements.

Additional information

Weight 2 lbs
Dimensions 9 × 9 × 9 in
Model

KEC115E Short Circuit and Over Current, VATOR, without Analog Output, KEC115E2 Short Circuit and Over Current, VATOR, without Analog Output, KEC115F Short Circuit and Over Current, without Analog Output, KEC115F2 Short Circuit and Over Current, without Analog Output, KEC115G Short Circuit and Over Current, without Analog Output, KEC115H Short Circuit and 2-level Over Current, Predictor, without Analog Output, KEC115H2 Short Circuit and 2-level Over Current, without Analog Output, KEC115H4 Short Circuit and 2-level Over Current, without Analog Output, KEC115H5 Short Circuit and 2-level Over Current, Predictor, without Analog Output, KEC115P Short Circuit and Over Current, VATOR, Predictor, without Analog Output, KEC115P2 Short Circuit and Over Current, Predictor, without Analog Output, KEC115P3 Short Circuit and Over Current, without Analog Output, KEC116E Short Circuit and Over Current, VATOR, with Analog Output, KEC116E2 Short Circuit and Over Current, VATOR, with Analog Output, KEC116F Short Circuit and Over Current, with Analog Output, KEC116F2 Short Circuit and Over Current, with Analog Output, KEC116G Short Circuit and Over Current, with Analog Output, KEC116H Short Circuit and 2-level Over Current, Predictor, with Analog Output, KEC116H2 Short Circuit and 2-level Over Current, with Analog Output, KEC116H4 Short Circuit and 2-level Over Current, with Analog Output, KEC116H5 Short Circuit and 2-level Over Current, Predictor, with Analog Output, KEC116P Short Circuit and Over Current, VATOR, Predictor, with Analog Output, KEC116P2 Short Circuit and Over Current, Predictor, with Analog Output, KEC116P3 Short Circuit and Over Current, with Analog Output, KEC117E Short Circuit and Over Current, VATOR, with Analog Output, KEC117E2 Short Circuit and Over Current, VATOR, with Analog Output, KEC117F Short Circuit and Over Current, with Analog Output, KEC117F2 Short Circuit and Over Current, with Analog Output, KEC117G Short Circuit and Over Current, with Analog Output, KEC117H Short Circuit and 2-level Over Current, Predictor, with Analog Output, KEC117H2 Short Circuit and 2-level Over Current, with Analog Output, KEC117H4 Short Circuit and 2-level Over Current, with Analog Output, KEC117H5 Short Circuit and 2-level Over Current, Predictor, with Analog Output, KEC117P Short Circuit and Over Current, VATOR, Predictor, with Analog Output, KEC117P2 Short Circuit and Over Current, Predictor, with Analog Output, KEC117P3 Short Circuit and Over Current, with Analog Output

Aux Supply

100-120VAC Aux Supply, 200-240VAC Aux Supply, 380-415VAC Aux Supply, 440-480VAC Aux Supply, 12-24VDC Aux Supply, 48VDC Aux Supply, 110VDC Aux Supply

Analog Output

Without Analog Output, 0-10mA Analog Output, 0-20mA Analog Output, 4-20mA Analog Output, 0-10VDC Analog Output